Hitachi Chromatography

A new UHPLC, designed for a new era, has emerged to lend indispensable support to your research.

We set out to view the issues from a new angle; visualizing the future with no preconceptions. Toward the realization of high resolution and high sensitivity, achieved through advanced technologies, our daring approach resulted in the ChromasterUltra Rs.

The future of UHPLC starts here and now.

 

Features

  • High resolution analysis is realized through the world's highest system pressure(140 MPa) *1
  • World-class analysis when combined with the high resolution separation column (LaChromUltra II) for UHPLC, which has 50,000 theoretical plates
  • High sensitivity and high resolution stand side by side thanks to the total reflection capillary flow cell design
  • A system compatible with both HPLC and UHPLC analyses
  • Features designed for operational excellence including the MEM column fitting(optional) with 140 MPa system pressure tolerance, the built-in Waste Tank, etc.
    *1: Among models sold in Japan, surveyed by Hitachi High-Technologies as of July 2013

UHPLC will support HPLC analyses

Excellent performance up to 140 MPa system pressure

Stable solvent delivery is realized for a broad range of pressure, as high as 140 MPa, by incorporating a new control technology (LBT: Liquid Beat Technology) into the Binary pump. Even for gradient analysis under high pressures, highly reproducible analyses are available. Moreover, ultra fast analyses are supported by improving the gradient response using an extremely low system volume.

Stable solvent delivery allows a broad range of analyses from UHPLC to HPLC

Stable solvent delivery is realized, independent of pressure and solvent composition, by incorporating LBT control and by correcting the bulk modulus of solvent. Stable analyses are achieved with 5 µm columns, 3 µm columns, and 1.9 µm columns.

High resolution

It has been generally accepted that high resolution analyses of impurities and structural analogs of synthetic compounds, such as medicines and chiral molecules, are challenging, even with UHPLC. Now, however, the newly developed high resolution column, LaChromUltra II, designed for UHPLC applications with system pressures up to 140 MPa can achieve more advanced separation analyses and industry-leading performance.

High sensitivity

A total reflection type capillary flow cell is incorporated into the diode array detector to cope with the increasing need for high sensitivity analyses of hazardous substances, genotoxic impurities, etc.

A high sensitivity flow cell with an optical path length of 65 mm is also available. In addition to high sensitivity analyses, carryover is reduced through the use of a double corkscrew mixer.

For more information, click:

http://www.hitachi-hightech.com/global/product_detail/?pn=ana-chromasterultra

High Performance Liquid Chromatograph Chromaster

HPLC for today and tomorrow

[Outstanding Performance]

Two performance capabilities supporting data reliability: the excellent reproducibility made possible by the pump and autosampler and the excellent stability of the column oven and detector.

[Easy-to-use]

Beyond the simplicity of operation and ease of use, a critical requirement for HPLC is ease of maintenance.

[Robustness]

The Hitachi reputation for instrument robustness and reliability continues with the Chromaster, which is made using stronger materials and is manufactured with Hitachi's strict quality control standards.

Features

 

 

 

For the different models click:

http://www.hitachi-hightech.com/global/product_detail/?pn=ana-chromaster

High Performance Liquid Chromatograph Chromaster® 5610 MS Detector

Hitachi Chromaster 5610 new mass detector

The Hitachi Chromaster 5610 is a new mass detector, designed for HPLC users, that is different from a large-scale mass spectrometer.

  • Improved chromatogram reliability
  • Easy acquisition of mass information
  • No need for special installation environment
  • Can be easily maintained

Features

For Improved Analysis Reliability!

There is an increasing need for mass spectrometry data to improve analytical accuracy or to compensate for the inexact analysis that standard HPLC detectors provide.

However, unlike HPLC detectors, mass spectrometers often require special site preparation for installation and highly skilled personnel for operation and maintenance, making it difficult for laboratories to justify one even when it could be an ideal solution.

The Chromaster 5610 is the solution for HPLC users who have refrained from introducing a mass spectrometer due to (1) site requirements, (2) usability, and (3) maintainability, which are typical barriers.

Hitachi Design Concepts

Compact tabletop design! Ideal footprint for any HPLC laboratory

  • With its space-saving compact design, the footprint is equivalent to that of a HPLC system.
  • The N2 gas usage has been reduced (maximum flow rate of 3.4 L/min). The system can be operated with a N2 gas cylinder.
  • Can be connected to an existing HPLC (Please inquire about the compatibility).

Usability Equivalent to an optical HPLC Detector

Instrument and method settings

Ease of use is achieved by eliminating complicated MS settings for those new to mass analysis.

The Chromaster 5610 is equipped with an auto-tuning function to provide optimized instrument conditions for HPLC users who are unfamiliar with the operation of mass spectrometers.

Measurement Results

Functions such as the contour display allow the verification of an overall chromatographic elution pattern. The user interface resembles that of a PDA detector so operations are as simple as using HPLC detectors.

Maintainability Equivalent to optical HPLC Detectors

Maintenance

When reduced sensitivity or contamination is suspected, the atmospheric-pressure ion filter can be removed for easy cleaning.

As the vacuum pump can keep running while the filter is being cleaned, the measurements can be started immediately after the maintenance.

For more information, click:

http://www.hitachi-hightech.com/global/product_detail/?pn=ana-chromaster-5610

High Performance Liquid Chromatograph Primaide

 

Affordable and robust HPLC system engineered for seamless integration and reliable analyses

High Performance Liquid Chromatography (HPLC) is utilized in a diverse range of fields, including medicine, food production, chemistry, and environmental science, making HPLC systems increasingly in-demand among the various types of analytical equipment. The Hitachi HPLC Primaide is designed for long-term, stable operation, and features both high reliability and great durability. It offers tremendous capability for everyday analysis.

Based on over 50 years of experience in the development and production of HPLC systems, Hitachi proudly introduces the Primaide. Make the most of your analytical equipment with Hitachi as the “Prime Aide” in your lab!

The best choice for personal use

Even in small to mid-scale facilities, individual operators see increasing opportunities to use multiple HPLC systems. Thanks to its simple design and front-access layout, maintenance of the Primaide is easy. Even a beginner at LC analysis can confidently operate the Primaide.

Excellent basic performance

The demand for HPLC systems with higher precision, better reproducibility, and improved stability is increasing daily. The Primaide is built according to strict specifications to meet stringent requirements. In addition, labs can apply the Primaide to an even wider range of applications by employing optional units, such as a sophisticated DAD(Diode Array Detector) and an autosampler cooler.

Reliable durability

Hitachi HPLC systems have earned a reputation as highly durable machines, and Primaide is no exception. Our strict production quality standards ensure both high performance and endurance. This standard extends to all equipment from systems to accessories.

System Features

Optional units mounted inside provide clean appearance

All principal options, including a degasser, gradient unit, and sample cooling system can be mounted inside the main body.

It is not necessary to make room for optional units.

Front access layout for improved operation and maintenance

Every module can be accessed and handled from the front. Since connections are arranged on the front side, it is easy to replace columns and manipulate the flow system. To support easier maintenance, the lamp and cell unit can also be accessed easily.

Leak sensors in all modules

Any leakage in the flow system is detected by leak sensors built into each module. After detection the system halts, ensuring improved safety and reliability.

Complete control with system manager

A control panel is not necessary, as everything can be controlled via the system manager. By installing a UI-pad (optional), each module can be controlled separately, in a conventional manner.

e-Line and USB

The e-Line is an advanced version of the existing D-Line. All modules are connected by an e-Line in a single chain, and all the communications are integrated. The use of digital signals improves the reliability of data transactions. The interface between the PC and equipment is via versatile USB. A wide range of PC types are supported, enabling flexible configuration.

GLP function

A Hg lamp is installed in the detector, and wavelengths in the UV range can be calibrated using its emission line (254 nm) (installed in the Primaide 1410 UV / 1430 DAD). Each module stores various types of quality assurance information, for improved data reliability.

For more information:

http://www.hitachi-hightech.com/global/product_detail/?pn=ana-Primaide

High-speed Amino Acid Analyzer L-8900

Our Amino Acid Analyzer, Model L-8900, is the culmination of the technology and expertise earned through our extensive experience in manufacturing amino acid analyzers for over 50 years.

Features

Unparalleled detection limits can be achieved - 3 pmol of aspartic acid using ninhydrin reaction methods.

Standard amino acid determination takes just 30 minutes (net) and physiological fluid determination can be carried out fully automatically in just 110 minutes.

For more information:

http://www.hitachi-hightech.com/global/product_detail/?pn=ana-l8900

 